| Model | E8Y-PR2C | E8Y-PR5C | E8Y-P1C | E8Y-P2C
E8Y-P2C-R |
E8Y-P5C
E8Y-P5C-R E8Y-P5B |
E8Y-PR2Y | E8Y-P5Y
E8Y-P5Y-R |
|
|---|---|---|---|---|---|---|---|---|
| Power supply voltage | DC 12 to 24 V±10% max. (with a ripple) | |||||||
| Current consumption | 50 mA max. | 75 mA max. | ||||||
| Pressure type | Differential pressure | |||||||
| Rated pressure range | 0 to 200 Pa | 0 to 500 Pa | 0 to 1 kPa | 0 to 2 kPa | 0 to 5 kPa | 0 to 200 Pa | 0 to 5 kPa | |
| Withstand pressure | 50 kPa | |||||||
| Applicable fluid (gas) | Non-corrosive gas and non-flammable gas | |||||||
| Linear
output |
Output current | - | - | - | - | - | 4 to 20 mA | |
| Permissible load
resistance |
- | - | - | - | - | 0 to 250 Ω | ||
| Compar-
ison output |
Output type | NPN open collector (NO/NC) *1 | ||||||
| Load current | 100 mA max. | |||||||
| Output applied
voltage |
DC 30 V max. | |||||||
| Residual voltage | 1.0 V max. (at 100 mA load current), 0.4 V max. (at 16 mA load current) *2 | |||||||
| Display
method |
Display | 3-digit 7-segment red LED | ||||||
| Indicator lamp | Orange LED displays comparison output OUT1 and OUT2 LED (1): OUT1, LED (2): OUT2 | |||||||
| Repeating accuracy | ±5 Pa | ±5 Pa | ±10 Pa | ±20 Pa | ±50 Pa | ±5 Pa | ±50 Pa | |
| Linearity | ±10 Pa | ±10 Pa | ±10 Pa | ±20 Pa | ±50 Pa | ±10 Pa | ±50 Pa | |
| Setting/Display resolution | 1 Pa | 1 Pa | 1 Pa | 10 Pa | 10 Pa | 1 Pa | 10 Pa | |
| Protection circuits | Reverse polarity protection, load short-circuit protection | |||||||
| Ambient temperature range | -10 to +55°C (with no condensation or icing) | |||||||
| Ambient humidity range | 25 to 85%RH (with no condensation) | |||||||
| Ambient storage
temperature range |
-25 to +65°C (with no condensation or icing) | |||||||
| Accessories | Mounting Brackets (A and B), instruction manual | |||||||